Inspection and testing for IBC

  • Legal foundations for inspection and testing

    Legal foundations for inspection and testing

    All IBCs are subject to mandatory repeated inspection and testing in intervals of 2 ½ years as of the date of the first (factory) inspection:

     

    Service after 2½ years

    Implemented by a BAM registered servicing body II, according to BAM-GGR 002 – Part B, Paragraph B 1.2.1, B 2.1 and B 3.1

    • Inspection of the external condition
    • Inspection of marking
    • Inspection of the function of the control equipment, i.e. all fittings of the container
    • Leakage test with air with an overpressure of 0.2 bar

     

    Service after 5 years

    Implemented by a BAM registered servicing body I, according to BAM-GGR 002 – Part A, Paragraph A 1.2.1,AB 2.1 and A 3.1

    • To be carried out in addition to the inspection after 2 ½ years:
    • Checking of compliance with the type testing certificate
    • Internal inspection

     

    Potentially required servicing work and installation materials are charged at cost. On request, we will prepare a cost estimate for you in advance.

Container/tank type
Prod. no.*
Residual quantity (l)
Medium
1. Is the leak indicator system visually intact? (leakage liquid filled up to the fill mark or the vacuum leak indicator within the green range).
Yes No
2. Which leakage fluid serves as the control fluid? (can be read on the type plate of the leak detector).
Antifrogen N Control fluid A (no longer available) Pancalor 02 (no longer available)
3. Is a new nameplate required for the tank? (e.g. is the plate partially or totally unreadable, stamp fields full).
Yes No
4. Are there any noticeable leaks anywhere on the tank? (e.g. leaking liquids on or in the vicinity of the tank, cracked weld seams).
Yes No
5. Are there any dents or deformities on the container? (e.g. crane lugs or base pallets deformed/cracked, dents on the container wall).
Yes No
6. Is the operating equipment damaged or defective? (e.g. pump defective/leaking, hoses or connections porous/cracked or leaking, safety valve defective or missing).
Ja Nein
Manufacturer*
Container/tank type
Prod. no.*
Type approval

(Please fill in all fields marked with *)

Choose location

On site At the factory

Customer/ Invoice address

New customer Regular customer
Company*
First name*
Last name*
Post code*
City*
Street*
Street number*
Country
Phone*
E-mail*
Your order number
Customer number
VAT ID no.*
Country court*
HRA/HRB number*

Container/tank data

Container/tank type
Prod. no.*
Residual quantity (l)*
Medium*
1. Is the leak indicator system visually intact? (leakage liquid filled up to the fill mark or the vacuum leak indicator within the green range)
Yes No
2. Which leakage fluid serves as the control fluid? (can be read on the type plate of the leak detector)
Antifrogen N Control fluid A (no longer available) Pancalor 02 (no longer available)
3. Is a new nameplate required for the tank? (e.g. is the plate partially or totally unreadable, stamp fields full).
Yes No
4. Are there any noticeable leaks anywhere on the tank? (e.g. leaking liquids on or in the vicinity of the tank, cracked weld seams).
Yes No
5. Are there any dents or deformities on the container? (e.g. crane lugs or base pallets deformed/cracked, dents on the container wall).
Yes No
6. Is the operating equipment damaged or defective? (e.g. pump defective/leaking, hoses or connections porous/cracked or leaking, safety valve defective or missing).
Yes No

Third-party container

Manufacturer
Container/tank type
Prod. no.
Type approval
In order to be able to ensure correct testing and inspection, we require the type approval for third-party containers to be forwarded in advance to the following e-mail address aftersales@seppeler.de
Your comment/details on special design, requests or anomalies
I have read and understood the privacy policy and hereby agree that my personal data may be stored and processed. My data is exclusively used for the purpose of the processing and answering of my enquiry. By submitting this contact form I consent to the processing.*
Please note that the findings of the last inspection and test must be made available. A test report of each inspection and test is to be kept by the IBC owner at least until the next inspection and test.